Inspection
Inspection Details
Equipment ID
4308
4308
Inspection Date
10/15/2025
10/15/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Relief Valve Pressure
n/a
n/a
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
n/a
n/a
External ID
6957dfe3-69db-4632-bf9b-b2725a99c549
6957dfe3-69db-4632-bf9b-b2725a99c549
Location
Cliffs Office Bldg
4801 S Cliff Ave, Independence, MO
Phone: (816) 795-8825
4801 S Cliff Ave, Independence, MO
Phone: (816) 795-8825
Owner
Attn: J.W. Franklin Co
J.W. Franklin Co
PO Box 573, WARRENSBURG, MO 64093
Phone: (660) 747-9854
Email: chris@jwfranklin.com
J.W. Franklin Co
PO Box 573, WARRENSBURG, MO 64093
Phone: (660) 747-9854
Email: chris@jwfranklin.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Phase I and Phase II inop. This is the only elevator in a medical center. This unit is due a re-inspection in 14 days or will be red tagged., per Mo Memo011 | 9/7/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | mach room door lock needs to be self locking | 9/14/2025 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | alarm bell an emg lt not working | 10/15/2025 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | Emg lt not working | 7/21/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emg bell not working | 7/21/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | mach room door not self locking | 7/21/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | In case of fire signage needed | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Cartop dirty | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Pit dirty | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm not working. Battery | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light not working. Battery | 9/1/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Phase 2 fire service keyswitch flaky and has broken bezel. Replace | 9/1/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | prior violation was not fixed , parts ordered |