Inspection
Inspection Details
Equipment ID
10831
10831
Inspection Date
1/4/2019
1/4/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Steve Sine
Steve Sine
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
28
28
External ID
04f5f054-977a-4a56-b419-0c2dcfa4c0a1
04f5f054-977a-4a56-b419-0c2dcfa4c0a1
Location
Ranken Technical College
4431 FINNEY AVE, SAINT LOUIS, MO
4431 FINNEY AVE, SAINT LOUIS, MO
Owner
Ranken Technical College
4431 FINNEY AVE, SAINT LOUIS, MO 63113-2811
4431 FINNEY AVE, SAINT LOUIS, MO 63113-2811
Billing
Attn: Ranken Technical College
4431 FINNEY AVE, SAINT LOUIS, MO 63113-2811
4431 FINNEY AVE, SAINT LOUIS, MO 63113-2811
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current state operating certificate in the elevator machine room. | 4/28/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The personnel answering the emergency phone shall be able to provide the location of the elevator. | 10/18/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a code compliant MCP including onsite documents. | 4/28/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 4/28/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | No | No | MCP evacuation procedures are required on-site. | 5/5/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. | 5/5/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work. | 5/17/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Battery lowering shall work. | 5/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces | No | No | There are signs of black mold in the machine room on sheet rock wall at bottom. Take corrective action as needed. | 7/29/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces | No | No | There are signs of black mold in the machine room on sheet rock wall at bottom. Take corrective action as needed. Violation still remains after 5/17/24 re-inspection. | 7/29/2024 |