Inspection
Inspection Details
Equipment ID
23849
23849
Inspection Date
1/10/2019
1/10/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Marcus Geno
Marcus Geno
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
15F/18R
15F/18R
External ID
9dd6a046-61d7-404c-acd8-d009663cf2dc
9dd6a046-61d7-404c-acd8-d009663cf2dc
Location
Bunge North America
1391 TIMBERLAKE MANOR PKWY, CHESTERFIELD, MO
1391 TIMBERLAKE MANOR PKWY, CHESTERFIELD, MO
Owner
MHBK Leasing & Finance
1251 AVENUE OF THE AMERICAS, NEW YORK, NY 10020-1103
1251 AVENUE OF THE AMERICAS, NEW YORK, NY 10020-1103
Billing
Attn: MHBK Leasing & Finance
1251 AVENUE OF THE AMERICAS, NEW YORK, NY 10020-1103
1251 AVENUE OF THE AMERICAS, NEW YORK, NY 10020-1103
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope size is 6mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | No | No | 2.20 - The hoist rope is 8mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Test emergency power. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope size is 6mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | No | No | 2.20 - The hoist rope is 8mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | Yes | No | Emergency power shall be tested. | 10/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 2.29.1 | No | No | Elevator number on COP shall be correct. Currently says elevator #1 but it is elevator #3. | 11/25/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 11/8/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.6 - Governor-rope tension devices | 8.11.2.1.5(g) | No | No | The tail sheave switch shall be wired per the manufactures’ specifications. | 12/17/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Emergency power operation shall be tested. | 10/8/2025 |