Inspection
Inspection Details
Equipment ID
25740
25740
Inspection Date
11/5/2025
11/5/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
20
20
External ID
cbbaf424-f50d-4aa6-ad42-55154b5951c8
cbbaf424-f50d-4aa6-ad42-55154b5951c8
Location
The Hill Apartments
2100 Boardman St, St. Louis, MO
Phone: (000) 000-0000
2100 Boardman St, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Draper and Kramer, Inc.
Draper and Kramer, Inc.
55 E Monroe St, Ste 3900, Chicago, IL 60603
Phone: (000) 000-0000
Email: modaacctg@draperandkramer.com
Draper and Kramer, Inc.
55 E Monroe St, Ste 3900, Chicago, IL 60603
Phone: (000) 000-0000
Email: modaacctg@draperandkramer.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | Yes | No | Increase Machine space illumination to 19 footcandles minimum | 6/30/2022 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | Yes | No | Increase Control space to 19 footcandles minimum | 6/30/2022 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 2.7.1 | Yes | No | Close Control space penetrations | 6/30/2022 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 2.7.3 | Yes | No | Control space door shall be self-closing, self-locking | 6/30/2022 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Close all hoistway penetrations | 6/30/2022 |
| A17.1-2016 : Elevators | 3.11 - Hoistway smoke control | 2.1.4 | Yes | No | If determined by the local building codes hoistway vent is not required. remove wood blocking and replace with 2hr rated closure | 6/30/2022 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 | Yes | No | Increase pit illumination to 10 footcandles minimum | 6/30/2022 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.6 Sump Pump Covers | Yes | No | Cover pit sump even with pit floor | 6/30/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | Yes | Yes | Install smoke detector in the Control space | 6/30/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | Yes | Yes | All Phase I Recall Devices Shall Be Tested | 6/30/2022 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/12/2025 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The video/text emergency communication means shall conform to A17.1 - 2019, Section 2.27. The text operation is not working. See MO Memorandum 013. A variance shall also be applied for. | 11/12/2025 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The video/text emergency communication means shall conform to A17.1 - 2019, Section 2.27. The text operation is not working. See MO Memorandum 013. A variance shall also be applied for. | 4/14/2026 |