Inspection
Inspection Details
Equipment ID
2046
2046
Inspection Date
1/25/2019
1/25/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Christopher Hughes
Christopher Hughes
Relief Valve Pressure
450
450
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
08bd9b4f-3661-409f-9751-705f0c9bd56d
08bd9b4f-3661-409f-9751-705f0c9bd56d
Location
Lee's Summit High School
400 SE BLUE PKWY, LEES SUMMIT, MO
400 SE BLUE PKWY, LEES SUMMIT, MO
Owner
Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081-3290
502 TRANSPORT DR, LEES SUMMIT, MO 64081-3290
Billing
Attn: Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081-3290
502 TRANSPORT DR, LEES SUMMIT, MO 64081-3290
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Overhead lighting in car is unguarded. | |||
MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)6 | Guide roller under car badly cracked and deteriorating. | |||
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency lights not working. | 1/19/2021 | |
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency alarm not working. | 1/19/2021 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Fan guard on ceiling not secured well enough, and hanging down. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Door reopening devices not working. | 8/20/2021 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Sheet metal skins on car doors coming loose, repair. | 8/20/2021 | |
A17.1-2016 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3 | x | no metal data tags | 1/19/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | x | car lts not guarded | 1/19/2022 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non elevator related items from machine room. | |||
A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.11.3.1.1(r) | x | Provide door restrictor on car doors. | 1/18/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)7 | Pit switch not accessible from landing, move closer to the door. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light switch is red in color. Change to black or white to avoid further confusion and safety. | |||
A17.1-2016 : Elevators | 2.14 - Code data plate | 8.11.2.1.2(hh) | Provide code data plate in machine room. | |||
A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.2.1.2(k) | Smoke detector in machine room has paint cover on it. | |||
MO Minimum : Elevators | (I) - Pits | (I)7 | Pit stop switch hidden, relocate for clear identification. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light switch is red in color, change to black or white to avoid confusion. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non elevator related items from machine room. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Provide covers for FFS modules in machine room. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working, alarm bell ok. | 9/27/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Provide door restrictors on both car doors. | 9/27/2023 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working. Line? | 4/1/2024 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Shunt trip not overriding emergency battery lowering. Need relay added | 4/1/2024 | |
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | Machine room door must be self-closing and self-locking | |||
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.4.19.6 | x | Top hoistway smoke sensor recalls elevator to wrong floor. Need relay added | 4/1/2024 | |
A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13 | Car door needs new leading edge stainless steel wrap around skin. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working on DC power, alarm bell ok. |