Inspection
Inspection Details
Equipment ID
7758
7758
Inspection Date
11/21/2025
11/21/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Justin Kennedy
Justin Kennedy
Relief Valve Pressure
n/a
n/a
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
26
26
External ID
015a37ec-d410-48d1-934b-deae3d4909a3
015a37ec-d410-48d1-934b-deae3d4909a3
Location
Glore Museum
3406 Frederick Ave, St. Joseph, MO
Phone: (816) 364-1209
3406 Frederick Ave, St. Joseph, MO
Phone: (816) 364-1209
Owner
Attn: Glore Museum
Glore Museum
3406 Frederick Ave, St. Joseph, MO 64506
Phone: (816) 232-8471
Email: anita@stjosephmuseum.org
Glore Museum
3406 Frederick Ave, St. Joseph, MO 64506
Phone: (816) 232-8471
Email: anita@stjosephmuseum.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency phone does not operate. | 10/12/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 10/11/2021 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state operating certificate inside machine room | 10/20/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 10/6/2022 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state operating certificate inside the machine room | 12/9/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 10/4/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Post In Case of Fire signage next to hall button fixture at each landing | 12/9/2025 | ||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not illuminate | 12/9/2025 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | State operating certificate not displayed in machine room | 12/9/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 2/4/2025 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | State operating certificate not displayed | 12/9/2025 | ||
| MO Minimum : Elevators | (I) - Pits | (I)5 | MOVE PIT LADDER TO HOISTWAY DOOR INTERLOCK SIDE OF PIT | 12/9/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | BOLT DOWN CAR TOP EMERGENCY EXIT | 12/9/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | EMERGENCY PHONE NOT WORKING | 12/9/2025 | |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)7 | x | INSTALL COVER ON 2ND FLOOR HOISTWAY INTERLOCK | 12/9/2025 |