Inspection
Inspection Details
Equipment ID
12090
12090
Inspection Date
1/11/2019
1/11/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
William Gorden, Jr.
William Gorden, Jr.
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
28/29
28/29
External ID
bab2fac7-bb16-452a-8a01-e7198e1a6566
bab2fac7-bb16-452a-8a01-e7198e1a6566
Location
Renaissance Grand Hotel
820 WASHINGTON AVE, SAINT LOUIS, MO
820 WASHINGTON AVE, SAINT LOUIS, MO
Owner
Attn: UNK
Marriott St Louis Grand
800 WASHINGTON AVE, SAINT LOUIS, MO 63101
Phone: (314) 418-5840
Email: karen.hinz@marriott.com
Marriott St Louis Grand
800 WASHINGTON AVE, SAINT LOUIS, MO 63101
Phone: (314) 418-5840
Email: karen.hinz@marriott.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Repair emergency lights in car. | 11/5/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency light not working. | 12/11/2020 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | Repair pit light. | 11/5/2025 |
| A17.1-1996 : Elevators | 3.22 - Wire rope fastening and hitch plate | 1001.2(c)(28) | No | No | Replace anti-rotation devices on counterweights. | 11/5/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light (still) inoperative. | 3/10/2021 |
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 1001.2(b)(15) | Yes | Yes | Car lowered, stopped and held 125% capacity, however adjustment needs to be made for brake pick gaps to a consistent .005 as per brake data tag. Reinspection only. | 3/28/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light and alarm bell do not work. | 3/28/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the elevator machine room | 11/5/2025 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | No | No | Repair or replace travel cable due to damage and/or breakage of cable insulation at basement floor loop | 11/5/2025 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | No | No | Repair/replace travel cable due to damage and/or breakage of cable insulation. Basement floor loop | 11/5/2025 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | No | No | Repair/replace travel cable due to damage and/or breakage of cable insulation. Basement floor loop | 3/11/2026 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | Yes | No | Repair/replace travel cable due to damage and/or breakage of cable insulation. Basement floor loop | 4/22/2026 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.3c | No | No | There shall be permanent means of temperature control inside of the elevator machine room. | 4/28/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.2-211.8 | Yes | Yes | Unit failed to perform firefighters operation and is red tagged at this time. | 4/28/2026 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.3c | No | No | There shall be permanent means of temperature control inside of the elevator machine room. |