Inspection
Inspection Details
Equipment ID
9822
9822
Inspection Date
6/1/2017
6/1/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Edward Jones Dome
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
Owner
America's Center
701 Convention Plaza, St. Louis, MO 63101
701 Convention Plaza, St. Louis, MO 63101
Billing
Attn: Edward Jones Dome
701 Convention Plaza, , MO 63101
701 Convention Plaza, , MO 63101
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Perform unit clean down | 3/31/2026 |
| conversion | conversion | n/a | No | No | Replace upper and lower comb sections with broken tooth, | 3/31/2026 |
| conversion | conversion | n/a | No | No | Replace step with broken tread fin, damage is located at tread riser intersection, | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Replace upper and lower comb sections with broken tooth. 7.7 | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | Replace step with broken thread fin. Damage is located at tread riser intersection. 7.9 | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(D) | No | No | Perform unit clean down. 8.6.8.13 | 3/31/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.14 | No | No | Clean out lower and upper pits. Relamp lower pit. | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform unit cleandown. | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Replace step with broken fin. Damage is located at tread riser intersection. | 7/15/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide written maintenance control program including wiring diagrams to be kept on site. | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.2 Escalator Step-to-Skirt Clearance | Yes | No | Perform step indexing test. | 7/20/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Maintenance logs need to be updated. | 3/31/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean upper and lower pits. | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Repair demarcation lighting in lower and upper end. | 7/20/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Repair demarcation lighting in the lower and upper end | 4/7/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean upper and lower pits | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Maintenance logs to be updated | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(H) | No | No | Replace light in lower pit area | |
| A17.1-2016 : Elevators | 7.5 - Lighting | 8.6.11.6.2(i) | No | No | The demarcation light fixtures failed to illuminate and shall be repaired/ replaced. | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | MCP shall be kept up to date | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | 3 steps have fins broken, 2 on the nose, one on the tread. Replace as needed |