Inspection
Inspection Details
Equipment ID
19509
19509
Inspection Date
1/8/2026
1/8/2026
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Michael Vantassel
Michael Vantassel
Relief Valve Pressure
NA
NA
Slide
TBD
TBD
Governor Rope Pull
100/330
100/330
Door Closing Force
TBD
TBD
External ID
1d6e1d68-6861-4435-9510-0e19fc441e9c
1d6e1d68-6861-4435-9510-0e19fc441e9c
Location
Trader's Building
801 N 2nd St, St. Louis, MO
Phone: (314) 421-2005
801 N 2nd St, St. Louis, MO
Phone: (314) 421-2005
Owner
Attn: Trader Building, LLC
Trader Building, LLC
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Email: invoices@advantesgrp.com
Trader Building, LLC
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Email: invoices@advantesgrp.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | This inspection was to allow temporary usage of the elevator. The temporary use inspection was stopped as the elevator would not pick the rated load. The 5 year testing required for the temporary usage inspection shall be completed. | 6/13/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Detector edge shall work (not currently installed). | 2/13/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-WAY Communication device shall work and be Code Compliant. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Clearance between car door panel and the car entrance jamb exceeds 13mm(0.5in) (COP jamb) | 2/13/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | No | No | COP shall be securely attached to cab interior. Currently leaning against wall. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car Door Restrictor shall work entire length of hoistway, when outside of door zones. (not currently installed) | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Roof Access door has disconnected/broken “hold open” latch. Safety hazard. | 2/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room door shall be self-closing and self-locking. | 2/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting needs to be repaired, 1 or more bulbs not working. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room shall have proper Fire Extinguisher and shall have current monthly/annual test tag. (Expired2016). | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Top emergency exit electrical contact shall work. (Switch not installed, Required as of 2000.) | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Top Emergence Exit shall be hinged or otherwise attached to the cartop(chain, etc) and properly secured (wingnut, etc) (currently not attached or bolted.) | |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | No | No | Hoistway doors have 2 escutcheon holes. Fill unused hole. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Remove unused/not required Heat detectors in Machine Room and Top of Hoistway orthey shall work properly. (no Sprinklers or Shunt). |