Inspection
Inspection Details
Equipment ID
16827
16827
Inspection Date
1/7/2026
1/7/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
400
400
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
20
20
External ID
46c49ddb-6737-4566-9914-65dad455cf0a
46c49ddb-6737-4566-9914-65dad455cf0a
Location
Interiors Unlimited
2149 SCHUETZ RD, SAINT LOUIS, MO
Phone: (314) 222-4060
2149 SCHUETZ RD, SAINT LOUIS, MO
Phone: (314) 222-4060
Owner
Attn: Lisa Lagermann
The Sherwin-Williams Co.
2145 Scheutz Rd, Ste 200, St. Louis, MO 63146
Phone: (314) 997-3706
Fax: (314) 997-1603
Email: lisa.a.lagermann@sherwin.com
The Sherwin-Williams Co.
2145 Scheutz Rd, Ste 200, St. Louis, MO 63146
Phone: (314) 997-3706
Fax: (314) 997-1603
Email: lisa.a.lagermann@sherwin.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In car emergency bell shall work. | 6/28/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency bell and light shall be operational. | 2/12/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. | 5/21/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | 2/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Top floor door pickup roller shall be replaced. | 5/22/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water on pit floor shall be removed. The pit shall be kept clean and dry. | 5/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired. An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 5/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | A code data plate shall be provided on the machine. | 5/22/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | All pits shall be kept dry, clean and free of equipment or materials not relating to the operation of the elevator. | 5/9/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit has approximately 12" of water. Pit shall be kept dry, remvove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak. | |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Pit sump pump is not working. Repair/replace as needed. | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light shall work. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | All cab lighting lamps shall work. 1 of 2 lamps not working. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine room walls covered in mold up to about 3' above the floor. Clean/replace as needed. |