Inspection
Inspection Details
Equipment ID
24912
24912
Inspection Date
1/16/2026
1/16/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Clinton Severs
Clinton Severs
Relief Valve Pressure
580
580
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
n/a
n/a
External ID
2f238c67-8201-4745-8051-dbaed3b8347d
2f238c67-8201-4745-8051-dbaed3b8347d
Location
St. Paul's Lutheran Church
207 N Owen St, California, MO
Phone: (573) 796-2735
207 N Owen St, California, MO
Phone: (573) 796-2735
Owner
Attn: St. Paul's Lutheran Church
St. Paul's Lutheran Church
207 N Owen St, California, MO 65018
Phone: (573) 796-2735
Email: office@stpaulslutheran1860.com
St. Paul's Lutheran Church
207 N Owen St, California, MO 65018
Phone: (573) 796-2735
Email: office@stpaulslutheran1860.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing | 2.4 | Yes | Yes | 5.2.1.4.4. low clearance | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 2.4.2 | Yes | No | 5.2.1.4.2. no protection | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | No | No | 5.2.1.1 not solid or fire proof | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.1.3.3 | No | No | 5.2.1.7.1. not solid or fire proof | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.1 - Car platform guard | 2.15.9 | No | No | 5.2.1.15.2. no platform guard | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | phone not working, no emergency light/bell | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 8.11.3.1.2 (q) | No | No | Rubber hose out of date | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | 5.2.1.12. Hoistway wiring not in conduit or protected. Car light not on single circuit | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.4 - Hoistway door locking devices | 2.12 | Yes | No | 5.2.1.12. runs with doors open, contacts at each floor no wired right | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 2.12.7 | Yes | Yes | 2.5.7.5.1. more than 5 inches between hoist door and car gate when door is closed | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.3 - Final and emergency terminal stopping devices | 2.25.3 | Yes | Yes | 5.2.2.13. top final | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | not self closing or locking | 1/16/2026 |