Inspection
Inspection Details
Equipment ID
7669
7669
Inspection Date
1/13/2026
1/13/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
25
25
External ID
fdec4880-b37e-41c0-8457-e4099f8d6efa
fdec4880-b37e-41c0-8457-e4099f8d6efa
Location
Calvary Cemetery Mausoleum
5239 W Florissant Ave, St. Louis, MO
Phone: (314) 792-7090
5239 W Florissant Ave, St. Louis, MO
Phone: (314) 792-7090
Owner
Attn: Tom Kuahner
Catholic Cemetaries- St. Louis
6901 Mackenzie Rd, St. Louis, MO 63123
Phone: (314) 575-6938
Fax: (314) 351-1782
Catholic Cemetaries- St. Louis
6901 Mackenzie Rd, St. Louis, MO 63123
Phone: (314) 575-6938
Fax: (314) 351-1782
Billing
Attn: Executive Assistant
Catholic Cemetaries- St. Louis
6901 Mackenzie Rd, St. Louis, MO 63123
Phone: (314) 792-7465
Fax: (314) 351-1782
Email: diana@stlcathcem.org
Catholic Cemetaries- St. Louis
6901 Mackenzie Rd, St. Louis, MO 63123
Phone: (314) 792-7465
Fax: (314) 351-1782
Email: diana@stlcathcem.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current fire extinguisher shall be mounted in the machine room located convenient to the access door. | 7/1/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/1/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | The electrical junction box under the car platform shall be covered. | 7/1/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-closing and self-locking. | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | 8.6.3.2.1 - Suspension cable anti-rotation devices shall be installed. | 7/1/2020 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | No | No | Suspension rope and governor rope tags shall be installed. | 7/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 6/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | 6/27/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 6/27/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | The electrical box on the underside of the car shall have a cover installed. | 6/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Suspension cables shall have an anti-rotation device installed. | 6/27/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/22/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 1/22/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water and oil shall not be allowed to accumulate on pit floor. The pit has about 3" of standing water in it. | 1/22/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit shall be kept free of exvessive water. |