Inspection
Inspection Details
Equipment ID
13581
13581
Inspection Date
1/26/2026
1/26/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Amador
Michael Amador
Mechanic Name
Jake Brennan
Jake Brennan
Relief Valve Pressure
450
450
Slide
0
0
Governor Rope Pull
na
na
Door Closing Force
15
15
External ID
92bb290c-fb0b-42b9-8393-93e0a86f7850
92bb290c-fb0b-42b9-8393-93e0a86f7850
Location
St. Louis Union Station
1800 Market St, St. Louis, MO
Phone: (314) 421-3314
1800 Market St, St. Louis, MO
Phone: (314) 421-3314
Owner
Attn: USH, LLC
USH, LLC
111 Westport Plaza Dr, Ste 500, St. Louis, MO 63141
Phone: (000) 000-0000
Email: rhargrove@stlunionstationhotel.com
USH, LLC
111 Westport Plaza Dr, Ste 500, St. Louis, MO 63141
Phone: (000) 000-0000
Email: rhargrove@stlunionstationhotel.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Elevator pit light is not working | 2/14/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Elevator alarm bell not working | 11/7/2019 |
| conversion | conversion | n/a | No | No | Machine room lights not working | 2/14/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.1.1 | Yes | No | Machine room penetrations | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Hoistway penetration NE corner | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.1.1 | Yes | No | Install ceiling in machine room | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.11.2.2.6 | Yes | No | Heat and smokes for shunt recall | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | Yes | No | Increase pit illumination to 10 ft candles throughout measured at the floor. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Enclose top hoistway | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | Yes | No | No oil minder on sump pump. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | Yes | No | Machine room illumination shall be 19 ft candles throughout measured at the floor. | 2/24/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide source power labels on disconnect switches. | 5/13/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 5/13/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in equipment room. | 5/13/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired, have serviced or replaced | 7/3/2024 |