Inspection
Inspection Details
Equipment ID
15890
15890
Inspection Date
2/2/2026
2/2/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Bradley Rasnake
Bradley Rasnake
Mechanic Name
Thomas Jimas
Thomas Jimas
Relief Valve Pressure
410
410
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
14
14
External ID
5c18e505-83ad-431e-8b04-0b30a2fbee16
5c18e505-83ad-431e-8b04-0b30a2fbee16
Location
City of Manchester
14317 Manchester Rd, Manchester, MO
Phone: (314) 393-2104
Email: mbecker@manchestermo.gov
14317 Manchester Rd, Manchester, MO
Phone: (314) 393-2104
Email: mbecker@manchestermo.gov
Owner
Attn: Public Works
City of Manchester
14318 Manchester Rd, Manchester, MO 63011
Phone: (636) 227-1825 Ext: 130
Email: publicworks@manchestermo.gov
City of Manchester
14318 Manchester Rd, Manchester, MO 63011
Phone: (636) 227-1825 Ext: 130
Email: publicworks@manchestermo.gov
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. | 3/11/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display Updated Missouri Operating Certificate in Machine Room | 2/10/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | No MCP program on site | 2/10/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communication in-operable. Re-inspection required | 8/28/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired, have serviced or replaced. | 2/10/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Smoke detectors are being replaced and added, there operation needs to be tested upon completion. Re-inspection required | 2/9/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.8 - Top emergency exit | 2.14.1.5 | No | No | Emergency exit cover shall be hinged or attached with a chain | 2/10/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 2/10/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communication inoperable. Re-inspection required | 2/9/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Smoke detectors are being replaced and added. Their operation shall be tested upon completion. Re-inspection required | 2/9/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room. | 2/10/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Smoke detectors are being replaced & added. Their operation shall be tested upon completion. Re-inspection required | 2/29/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.4.19.6 | Yes | No | Machine room detector not programed to alarm or flash the hat as required by code | 3/29/2024 |