Inspection
Inspection Details
Equipment ID
3657
3657
Inspection Date
11/29/2017
11/29/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
Over 30
Over 30
External ID
Location
Sky 11
331Park Central Square East, Springfield, MO
Phone: (314) 650-8537
331Park Central Square East, Springfield, MO
Phone: (314) 650-8537
Owner
Downtown Springfield Properties
333 Park Central Square East, Ste 214, Springfield, MO 65806-2225
333 Park Central Square East, Ste 214, Springfield, MO 65806-2225
Billing
Attn: Vecino Group
305 W Commercial St, , MO 65803
305 W Commercial St, , MO 65803
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room. | 5/15/2024 |
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Replace GFCI in pit | 5/15/2024 |
| conversion | conversion | n/a | No | No | Door torque over 30 pounds. Adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Need current fire extinguisher in machine room | 5/15/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 10/16/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Clean Machine Room | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No Maintenance Records | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to machine room (height of approximately 25' with an angle of 70% ) | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fireman's recall is to be checked monthly | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch requires replacing | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No Records | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Ladder for Egress/Access to equipment room needs a back cover ladder approximately 25' @ an angle of about 75 degree. | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Ropes under sized | 5/20/2024 |