Inspection
Inspection Details
Equipment ID
5636
5636
Inspection Date
3/9/2026
3/9/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Thomas Suedkamp
Thomas Suedkamp
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
Freight Doors
Freight Doors
External ID
05e1e3f4-fd89-4b42-a499-2890d9f11830
05e1e3f4-fd89-4b42-a499-2890d9f11830
Location
Bayer R&D
700 Chesterfield Pkwy W, Chesterfield, MO
Phone: (000) 000-0000
700 Chesterfield Pkwy W, Chesterfield, MO
Phone: (000) 000-0000
Owner
Attn: David Walter
Bayer Research and Development Services LLC
700 Chesterfield Pkwy W, Chesterfield, MO 63017
Phone: (314) 682-8665
Email: david.walter.ext@bayer.com
Bayer Research and Development Services LLC
700 Chesterfield Pkwy W, Chesterfield, MO 63017
Phone: (314) 682-8665
Email: david.walter.ext@bayer.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | New hoistway penetrations shall be sealed (at the top floor). | 6/21/2019 |
| conversion | conversion | n/a | No | No | Wiring not related to the elevator shall not be added to the hoistway (at the top floor). | 6/21/2019 |
| conversion | conversion | n/a | No | No | A 2nd heat detector is required withing 24" of the second fire sprinkler head in hoistway overhead. | 6/21/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 2.2.3 - Safety screen mesh shall be installed between two hoistways. Passenger hydraulic on backside of freight car shall have a divider. | 6/27/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Up to date operating certificate is required in the machine room. | 6/27/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Yes | No | Some of the machine room walls have been torn down and are missing. It's currently open and without a door. The elevator machine and control equipment shall be located in a separate room or separated space designed as an elevator machine room or space and shall be accessible only to authorized personnel. | 1/21/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Yes | No | All rooms or enclosures shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 1/21/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 6/27/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The in-car emergency light shall be operational. | 1/21/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 6/27/2025 |
| MO Minimum : Elevators | (J) - Counterweights | (J)2 | Yes | No | Counterwight is on springs when car reached top final limit. Runby must be a minimum of 6 inches". Suspension ropes must be shortenend. |