Inspection
Inspection Details
Equipment ID
25202
25202
Inspection Date
3/2/2026
3/2/2026
Inspection Type
Reinspection
Reinspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Michael Kennedy
Michael Kennedy
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
cb37502e-d865-42cc-b9c5-d70f5913734d
cb37502e-d865-42cc-b9c5-d70f5913734d
Location
Centene Plaza Bldg C - Retail #1
7676 Forsyth Blvd, Clayton, MO
Phone: (314) 721-8427
Email: onsite@rafcoprop.com
7676 Forsyth Blvd, Clayton, MO
Phone: (314) 721-8427
Email: onsite@rafcoprop.com
Owner
Attn: Centene Center I, LLC c/o Rafco Properties
Centene Center I, LLC c/o Rafco Properties
7700 Forsyth Blvd, Ste 100, Clayton, MO 63105
Phone: (314) 721-8427
Email: onsite@rafcoprop.com
Centene Center I, LLC c/o Rafco Properties
7700 Forsyth Blvd, Ste 100, Clayton, MO 63105
Phone: (314) 721-8427
Email: onsite@rafcoprop.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.1 - Runways | 2.1.1.1 | Yes | No | The interior of the runway enclosure shall present a smooth surface on all sides. | 1/11/2021 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.1 - Runways | 2.1.1.3 | Yes | No | The lift side of the landing doors and sill shall present a smooth surface located not closer than 10mm (0.375 in.) nor more than 20mm (0.75 in.) from the access edge of the platform floor. | 1/11/2021 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.10 - Operating Devices and Control Equipment | 2.10 | Yes | No | The platform disconnect shall be located in sight of the motor controller. | 1/11/2021 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | A18.1 - 2.1.6.5 - A pit stop switch is required near the lower level entrance door. | 6/14/2022 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.1 - Runways | 2.1.1.3 | No | No | Reduce the opening speed of the lower level hoistway door. | 10/6/2025 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.7 - Capacity, Speed, and Travel | 2.7.2 | No | No | A capacity tag is required to be posted on the platform. | 10/6/2025 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.1 - Runways | 2.1.1.4 | No | No | Adjust the lower level interlock so that it is functional when the lower level door closes. | 10/6/2025 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | Yes | No | A18.1 - 2.1.7 - There is a disconnect inside the tower that does not appear to work. | 6/14/2022 |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | No | No | RECOMMENDATION: It is recommended that a warning sign be installed on the interior kitchen door that a wheelchair lift door may open. Note: The lift opens directly into a kitchen entry door. | 10/6/2025 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | CSR 40-5.100 State Operating Certificate | 5.100(2)Display of Certificate | No | No | A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it. | 10/6/2025 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.11 - Emergency Signals | 2.11.2 | Yes | No | Emergency communications are not working. | 2/12/2026 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.6 - Platforms | 2.6.6.3 | Yes | No | Emergency light shall work. | 2/12/2026 |
| ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts | 2.6 - Platforms | 2.6.6.3 | Yes | No | Emergency light shall work. | 3/17/2026 |