Inspection
Inspection Details
Equipment ID
5773
5773
Inspection Date
3/11/2026
3/11/2026
Inspection Type
Reinspection
Reinspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Steven Himmelmann
Steven Himmelmann
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
89366f6c-a972-452f-bae9-fd378d316faf
89366f6c-a972-452f-bae9-fd378d316faf
Location
Elimwood Hotel
13735 Riverport Dr, Maryland Heights, MO
Phone: (314) 298-3400
13735 Riverport Dr, Maryland Heights, MO
Phone: (314) 298-3400
Owner
Attn: Kal Hastings/Lindsey Whitmah
Elimwood LLC
13735 Riverport Dr, Maryland Heights, MO 63043
Phone: (314) 298-3400
Email: khastings@hmahotels.com
Elimwood LLC
13735 Riverport Dr, Maryland Heights, MO 63043
Phone: (314) 298-3400
Email: khastings@hmahotels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Front door restrictor shall work - re-inspection required | 9/6/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | The ventilation HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller. | 3/18/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.30 - Hydraulic Power Unit | 8.11.3.1.2(m) | No | No | The main starter relay malfunctioned when performing the annual test. The relay shall be repaired and a reinspection will be required to complete the annual inspection. | 3/18/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The elevator machine room door shall be repaired to be self-closing and self-locking and shall be operable from the interior space without the use of a key. The machine room door shall remained closed and accessible to authorized personnel only. | 3/18/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Need to pump oil from pit and clean. | 3/18/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | EXCESSIVE OIL LEAKING FROM CONTROL VALVE | 2/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | NO MCP IN MACHINE ROOM | 12/12/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | The ventilation HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller. | 2/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | WIRE RACEWAY COVERS MISSING - EXPOSED WIRNG | 12/12/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | PHASE ONE KEY SWITCH BEZEL ILLEGIBLE | 12/12/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | PHASE ONE INSTRUCTIONS MISSING | 12/12/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | EXCESSIVE CLOSING FORCE ON REAR DOORS | 12/8/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | MISSING GIBB ON 2ND FLOOR HOISTWAY DOOR | 12/8/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | CAR TOP LIGHTING INADEQUATE | 12/12/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | MACHINE ROOM DOOR NOT SELF CLOSING / LOCKING | 2/18/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 12/12/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove full 5 gallon oil container from pit, clean pit | 12/12/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Cartop need cleaning | 12/12/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door is missing keeper in door jamb, replace same | 2/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Fire service phase I keyswitch bezel is illegible, needs to be replaced | 12/12/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Control valve & pump unit leaks excessively causing pans under pump unit to overflow. Remove oil from pans, remove oil soaked pads from machine room, clean floor and repair leaks to prevent this condition. | 2/18/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Rear doors ceased operating during testing. Perform fire service tests. Re-inspection required | 6/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.7 Record of Oil Usage | No | No | Accurate written oil loss / replacement records shall be kept as part of maintenance control program | 2/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Replace missing hoistway door gib on 2nd floor door | 12/12/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A cop of the current state operating certificate needs to be properly displayed in machine room | 11/26/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door is missing keeper in door jamb. | 11/26/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | control valve & pump unit leaks excessively causing pans under pump unit to overflow. Remove oil from pans, remove oil soaked pads from machine room, clean floor and repair leaks to prevent this condition. | 2/18/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate needs to be properly displayed in machine room. | 11/26/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door is missing keeper in door jamb. Replace same. | 11/26/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Yes | No | Control valve and pump unit leaks EXCESSIVELY, causing pans under pump unit to overflow. Remove oil from pans, remove oil soaked pads from machine room floor, clean floor and repair leaks to prevent this condition. Repair and reinspect in 14 days | 3/29/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Permanent means of temperature control are inoperable and shall be repaired or replaced. | 2/18/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Sight guard on hoistway doors at at the top landing is loose and shall be replaced or repaired. | 2/18/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | Yes | Car does not go into Phase II fire service, Red-tagged, Re-inspection required | 3/17/2026 |