Inspection
Inspection Details
Equipment ID
21902
21902
Inspection Date
1/21/2019
1/21/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Robert Kehm
Robert Kehm
Relief Valve Pressure
Slide
Instantaneous
Instantaneous
Governor Rope Pull
80/400
80/400
Door Closing Force
NA
NA
External ID
c5e16e90-d031-4c29-91fb-574c79638b3b
c5e16e90-d031-4c29-91fb-574c79638b3b
Location
Doe Run Company
1382 SWEETWATER MINE RD, ELLINGTON, MO
1382 SWEETWATER MINE RD, ELLINGTON, MO
Owner
Doe Run Company
1382 SWEETWATER MINE RD, ELLINGTON, MO 63638-9166
1382 SWEETWATER MINE RD, ELLINGTON, MO 63638-9166
Billing
Attn: Doe Run Company
1382 SWEETWATER MINE RD, ELLINGTON, MO 63638-9166
1382 SWEETWATER MINE RD, ELLINGTON, MO 63638-9166
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | Yes | Hoistway door locks shall not allow the elevator to run with the door open. | 1/25/2022 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)2 | Yes | Yes | Final limits shall not allow the elevator to run when the switch is open. | 1/25/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | A sill guard shall be installed. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Replace the missing cover on the traveling cable junction box under the car. | 6/7/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. | 6/7/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall be operational. | 6/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | A working emergency light shall be provided. | 1/25/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | A working alarm bell with a 4 hour battery back-up shall be provided. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/7/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | A sill guard shall be installed. | 1/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Replace the missing cover on the traveling cable junction box under the car. | 6/7/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall be operational. | 6/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | A working emergency light shall be provided. | 1/18/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | A working alarm bell with a 4 hour battery back-up shall be provided. | 1/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Shall have working emergency light and alarm with 4 hour battery back up. (2nd Notice) | 6/7/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | When car top inspection station is activated, control of the elevator shall only be operable from the car top inspection station. Currently the car controls are operational while on car top inspection. Take corrective action. | 6/27/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Top of car stop switch shall be operational. | 3/31/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | Yes | No | 2nd and 3rd floor hoistway doors shall be self-closing. Take corrective action as needed. | 3/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2 On-Site Documentation | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 3/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | Yes | Emergnecy light does not work. | 5/15/2026 |