Inspection
Inspection Details
Equipment ID
13410
13410
Inspection Date
2/6/2019
2/6/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
23
23
External ID
ad24753f-d3ef-4282-81c2-228ca5f7c675
ad24753f-d3ef-4282-81c2-228ca5f7c675
Location
Holiday Inn-St. Louis Downtown
811 N 9TH ST, SAINT LOUIS, MO
811 N 9TH ST, SAINT LOUIS, MO
Owner
HMA Hotels
811 N 9TH ST, SAINT LOUIS, MO 63101-2902
811 N 9TH ST, SAINT LOUIS, MO 63101-2902
Billing
Attn: Holiday Inn-St.Louis Downtown Convention Center
811 N 9TH ST, SAINT LOUIS, MO 63101-2902
811 N 9TH ST, SAINT LOUIS, MO 63101-2902
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Remove Oil from pit floor | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Clean pump unit from drip pan | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Clean oil from Machine room floor | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Repair machine room door lock | 7/15/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Certificate in machine room | 7/15/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Unit out of service. Make all repairs in order for an inspection to occur. | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 4/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide a complete maintenance control program and include oil log | 4/27/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lighting | 4/27/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test and document on log in machine room | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor. Sump hole filled with oil spilling out all over floor. Written up last years inspection | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Car emergency communications not working | 3/13/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lighting | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor. Reinspection required within 14 days. Fire hazard | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car . Reinspection required within 14 days | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair emergency light in car |