Inspection
Inspection Details
Equipment ID
12258
12258
Inspection Date
2/5/2019
2/5/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Charles Brinkman
Charles Brinkman
Mechanic Name
Bryan Hesskamp
Bryan Hesskamp
Relief Valve Pressure
N/A
N/A
Slide
Governor Rope Pull
Door Closing Force
N/A
N/A
External ID
6482ed5a-78ca-4a4d-b797-0f4684fde7a0
6482ed5a-78ca-4a4d-b797-0f4684fde7a0
Location
Thrive St. Louis Inc
4331 LINDELL BLVD, SAINT LOUIS, MO
4331 LINDELL BLVD, SAINT LOUIS, MO
Owner
Thrive St. Louis Inc
4331 LINDELL BLVD, SAINT LOUIS, MO 63108-2701
4331 LINDELL BLVD, SAINT LOUIS, MO 63108-2701
Billing
Attn: Thrive St. Louis Inc
4331 LINDELL BLVD, SAINT LOUIS, MO 63108-2701
4331 LINDELL BLVD, SAINT LOUIS, MO 63108-2701
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | 1. Each passenger car shall have lighting inside the enclosure of not less than five (5) foot-candles. Bulbs and tubes shall be guarded to prevent breakage. Bulbs are not guarded. | 2/6/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | Yes | 2. Each hoistway landing in any elevator hoistway shall be continuously provided with a properly working door or gate. The hoistway door on the bottom landing (basement) does not open the full distance of the entrance opening which causes the elevator to become stuck and possibly creating an entrapment. | 2/5/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | 3. The top emergency exit shall be locked, and openable from the top of the car only without the use of special tools. Also the exit is hinged or otherwise attached to the car. The emergency exit is not locked or attached to cartop. Ref: A17.2 3.8 | 2/6/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | 4. In checking the condition of the leading edges of the entrance panels the door striking recess on the hoistway side is rusted out and cutout leaving a bad condition for someone to become cut or injured at ankle or shin level if not careful. Ref: A17.2 4.2.1(b)(3) | 2/6/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | 5. All pits shall be kept dry, clean and free of equipment or material not relating to the operation of the elevator. Pit is wet and has water saturated rags and such. | 2/6/2020 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 | No | Yes | 6. A plunger gripper, where provided, shall be inspected and tested. This was not tested per code for a 5-year test. Ref: 8.11.3.4.4 | 2/5/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | 1) Each passenger car shall have lighting inside the enclosure of not less than five (5) foot-candles. Bulbs and tubes shall be guarded to prevent breakage. Bulbs are not guarded. Ref: (B) 8 | 2/6/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | 2) All pits shall be kept dry and clean. Pit has oil from leaking 90 elbow entering the pit. This needs to be replaced. Ref: (I) 1 | 2/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide maintenance records on site for review. | 12/1/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine space lighting shall be a 10 foot candle minimum at floor. Current lighting is powered by elevator controls and do not work when the elevator power is removed to work on unit | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water in the pit shall be removed. Sump pump in pit appears to not be working. Repair or replace | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine space is expired. Replace or have serviced | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11.1.4(a) Elevators Placed in Inactive Status | Yes | Yes | Unit removed from service, placed Inactive. Red tag was placed. |