Inspection
Inspection Details
Equipment ID
15911
15911
Inspection Date
2/8/2019
2/8/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
30
30
External ID
40d442b2-e914-4f6f-89ee-fc0f323f64e6
40d442b2-e914-4f6f-89ee-fc0f323f64e6
Location
Marriott Towneplace Suites
4026 ARIZONA AVE, JOPLIN, MO
4026 ARIZONA AVE, JOPLIN, MO
Owner
O'Reilly Hospitality
2808 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4079
2808 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4079
Billing
Attn: Marriott Towneplace Suites
4026 ARIZONA AVE, JOPLIN, MO 64804-3221
4026 ARIZONA AVE, JOPLIN, MO 64804-3221
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 1.6 telephone will not call out---suspect phone | 2/8/2019 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | No | No | H-4 non elevator items stored in machine room need to be removed | 11/6/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired and discharged) | 12/8/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired and discharged) | 11/9/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | H(2) / 101.3d(1)(b)/2.7.3.4 Machine room door shall be self-closing and self-locking. Keep door closed | 3/24/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | H(4)/2.5/8.11.2.1.2(e). Non-elevator related items shall not be stored in Machine Room. | 3/24/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location. Failed to connect. REINSPECTION REQUIRED | 10/27/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | B(8) Cab lighting shall be guarded to prevent breakage | 3/24/2022 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 1001.2(a)(14) | No | No | G(1)/1.14.1/1001.2(a)(14) Cab forced ventilation fan shall work Properly, very noisy and slow. | 3/24/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No MPC on site | 11/9/2022 |