Inspection
Inspection Details
Equipment ID
1468
1468
Inspection Date
4/10/2026
4/10/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Relief Valve Pressure
560
560
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
25 lbs
25 lbs
External ID
27b3de8f-b68e-46b8-b4a1-fbb845a2c90e
27b3de8f-b68e-46b8-b4a1-fbb845a2c90e
Location
Macy's Galleria
1550 Saint Louis Galleria, St. Louis, MO
Phone: (314) 522-5735
Email: PRESS@BPRETAIL.COM
1550 Saint Louis Galleria, St. Louis, MO
Phone: (314) 522-5735
Email: PRESS@BPRETAIL.COM
Owner
Attn: Macy’s -MSOC 3rd Floor
Macy’s -MSOC 3rd Floor
237 Woodbridge Center Dr., Woodbridge, NJ 07095
Phone: (000) 000-0000
Macy’s -MSOC 3rd Floor
237 Woodbridge Center Dr., Woodbridge, NJ 07095
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned | 3/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair leaking control valve | 3/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove oil recovery system from pit | 3/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Remove oil & trash from pit floor | 3/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair light on top of car | 3/1/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log in machine room | 3/1/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Provide phase 2 instructions in the car | 3/1/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 3/1/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Provide State certificate in machine room--not done | 3/1/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 3/1/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 3/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Clean excess oil & lint from the rails (fire hazard) | 3/1/2021 |
| A17.1-1996 : Elevators | 2.32 - Control Valve | 1004.2(b)(15) | No | No | Repair leaking control valve | 3/1/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 12/31/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 12/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Clean excess oil lint from the rails (fire hazard) | 12/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair leaking control valve | 12/31/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate for all units in machine room (still in violation) | 12/31/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 12/31/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Oil leaking in pit to be corrected and then clean pit | 12/31/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Yes | No | Post current state certificate in machine room. | 4/10/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | Yes | No | Perform monthly fire service testing and document on log in machine room | 4/10/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | Yes | No | Clean excess oil lint from the rails (fire hazard) | 4/10/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Yes | No | Post current state certificate for all units in machine room (still in violation) | 4/10/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | Yes | No | Perform monthly fire service and document on log in machine room | 4/10/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Yes | No | Oil shall be removed from pit floor. | 4/10/2026 |