Inspection
Inspection Details
Equipment ID
11055
11055
Inspection Date
1/23/2019
1/23/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Richard Toeniskoetter
Richard Toeniskoetter
Relief Valve Pressure
640
640
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
8599fd82-24fb-4e8a-9e06-ff5430fbabb4
8599fd82-24fb-4e8a-9e06-ff5430fbabb4
Location
Social science Bldg
4601 MID RIVERS MALL DR, SAINT PETERS, MO
4601 MID RIVERS MALL DR, SAINT PETERS, MO
Owner
St. Charles Co Comm College
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376-2865
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376-2865
Billing
Attn: St. Charles Co Comm College
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376-2865
4601 MID RIVERS MALL DR, SAINT PETERS, MO 63376-2865
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Recommend packing be monitored for possible oil leak. | 10/22/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept dry. | 10/22/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | 5.11 - There is hydraulic fluid in the pit. Determine and correct the source of the leak. | 10/22/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 10/22/2025 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide a code compliant MCP including onsite documents. | 10/22/2025 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. | 10/22/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 10/22/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | Pit shall be kept clean and dry. Remove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak. | 10/22/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/22/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/22/2025 |