Inspection
Inspection Details
Equipment ID
2142
2142
Inspection Date
5/6/2026
5/6/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Brenton Lane
Brenton Lane
Relief Valve Pressure
350
350
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
21
21
External ID
81c9e858-4e84-477c-9064-e2d919505b3d
81c9e858-4e84-477c-9064-e2d919505b3d
Location
St. Raymond's Apartments
1015 Park Ave, St. Louis, MO
Phone: (314) 241-7838
1015 Park Ave, St. Louis, MO
Phone: (314) 241-7838
Owner
Attn: Owner/Manager
St. Raymonds Apts Assoc. LP
1015 Park Ave., St. Louis, MO 63104
Phone: (314) 241-7838
Email: themphill@thecapitalrealty.com
St. Raymonds Apts Assoc. LP
1015 Park Ave., St. Louis, MO 63104
Phone: (314) 241-7838
Email: themphill@thecapitalrealty.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone. | 6/24/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/8/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall not be used to store non-elevator related equipment. | 7/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work. | 9/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | In car stop switch shall be conspicuously and permanently marked "STOP" and shall indicate the stop and run positions; Faded and Unreadable. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Telephone Door Handle is missing. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | COP shall have car number displayed(multiple units onsite) | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting needs to be repaired, 1 or more bulbs not working. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Phone box obstructs the fully opening of the card rack. Relocation phone box. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Outlet is overloaded. 3 separate heating systems plugged into 1 outlet, Phone system plugged into other outlet. No available outlets for tools. Heating systems shall be permanently/properly wired . | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Phone box is wired to an extension cord that runs across the controller to an adapter installed in the machine room light fixture (Non-compliant). Remove extension cord and properly power phone box. |