Inspection
Inspection Details
Equipment ID
4227
4227
Inspection Date
2/4/2019
2/4/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Matthew O'Brien
Matthew O'Brien
Relief Valve Pressure
n/a
n/a
Slide
Governor Rope Pull
Door Closing Force
n/a
n/a
External ID
8e0dcbb3-17c7-46d0-8621-33d50b2752de
8e0dcbb3-17c7-46d0-8621-33d50b2752de
Location
Truman Farm Villa Apt
5306 HARRY S TRUMAN DR, GRANDVIEW, MO
5306 HARRY S TRUMAN DR, GRANDVIEW, MO
Owner
Attn: Steadfast Companies
Steadfast Companies
5300 HARRY S TRUMAN DR, GRANDVIEW, MO 64030
Phone: (816) 966-0500
Email: trumanfarm@steadfastliving.com
Steadfast Companies
5300 HARRY S TRUMAN DR, GRANDVIEW, MO 64030
Phone: (816) 966-0500
Email: trumanfarm@steadfastliving.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | replace missing hoistway pick up rollers on the middle landing | 2/4/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | replace the emergency light battery | 1/30/2019 | ||
MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | Perform monthly fire service test and post the log in the machine room | 2/19/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | clean up pit, oil in pit, pit can overflowing | 2/19/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | replace the cylinder packing, pit can overflows between service visits | 2/19/2020 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | Building lost power just as we were starting the inspection, schedule reinspection when building power has been restored | 1/26/2021 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | post a new copy of the state Certificate in the machine room every year | 2/19/2021 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The pit light does not work, replace light bulb | 2/19/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | fire service is not working, turned the phase 1 keyswitch and nothing happened. | 2/1/2021 |
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | machine room light is burnt out, replace bulb | 1/27/2022 | ||
MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | monthly fire service test log is not posted in the machine room, perform fire service test monthly and keep a test log in the machine room | 1/27/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | emergency phone line is dead, provide working phone line | 12/19/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | In case of fire don't use elevator signage needed | 3/7/2024 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Lighting below 10 foot candles | 3/7/2024 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Fire extinguisher out of date | 3/7/2024 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit needs cleaning | 3/7/2024 | ||
MO Minimum : Elevators | (I) - Pits | (I)8 | Pit sump hole needs cover | 3/7/2024 |