Inspection
Inspection Details
Equipment ID
59
59
Inspection Date
1/31/2019
1/31/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Christopher Bolin
Christopher Bolin
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
22
22
External ID
17d86d7b-8e0f-442a-88c2-664632391454
17d86d7b-8e0f-442a-88c2-664632391454
Location
Colony Plaza
404 SAINT LOUIS AVE, EXCELSIOR SPRINGS, MO
404 SAINT LOUIS AVE, EXCELSIOR SPRINGS, MO
Owner
Colony Plaza LP
40 COURT ST STE 650, BOSTON, MA 00000
40 COURT ST STE 650, BOSTON, MA 00000
Billing
Attn: Colony Plaza
404 SAINT LOUIS AVE, EXCELSIOR SPRINGS, MO 64024-2174
404 SAINT LOUIS AVE, EXCELSIOR SPRINGS, MO 64024-2174
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Perform monthly fire service test and post log in the machine room | 3/13/2020 |
| A17.1-2016 : Elevators | 1.12 - Car enclosure | 8.11.2.1.1(l) | No | No | replace car riding direction lantern lens that is missing, the hole was covered with duck tape | 5/25/2022 |
| A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | replace missing hoistway door pick up roller | 5/25/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Monthly fire service test log has not been filled out since June 2021 | 5/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | monthly fire service test log in the machine room was last filled out on December 2021, could not find a 2022 or 2023 fire service test log in the machine room | 3/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | clean up oil on the car top, it is starting to leak into the cab | 3/6/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Replace burnt out pit light bulbs | 3/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | clean the pit | 3/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The alarm bell didn’t work on battery power | 5/14/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.11.2.1.5(b) | Yes | No | Shorten ropes, runby is 4”with spring buffers | 5/14/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | New power cable ran through the block wall in the machine room needs to be Fire caulked and flex needs to be secured to the wall. | 3/12/2026 |