Inspection
Inspection Details
Equipment ID
11759
11759
Inspection Date
2/11/2019
2/11/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
490
490
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
b58c70db-83f7-4c03-88f3-776063d11713
b58c70db-83f7-4c03-88f3-776063d11713
Location
Homestead Studio Suites
11252 LONE EAGLE DR, BRIDGETON, MO
11252 LONE EAGLE DR, BRIDGETON, MO
Owner
Attn: UNK
Extended stay Hotels C/O Lerch Bates
4201 Northview Drive, Ste 314, Bowie, MD 20716
Phone: (240) 548-3119
Fax: (240) 548-3119
Email: Extendedstay.elevators@lerchbates.com
Extended stay Hotels C/O Lerch Bates
4201 Northview Drive, Ste 314, Bowie, MD 20716
Phone: (240) 548-3119
Fax: (240) 548-3119
Email: Extendedstay.elevators@lerchbates.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair emergency light & bell in car | 7/2/2019 |
| conversion | conversion | n/a | No | No | Adjust car door restrictor | 7/2/2019 |
| conversion | conversion | n/a | No | No | Repair pit light | 7/2/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 8/20/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 6/17/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Need maintenance control program on site posted on controller | 6/17/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Muffler on oil line leaking badly when testing | 6/17/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 6/7/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 6/7/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Replace backup battery for the phone in car | 10/14/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Unit Red Tagged during overspeed test muffler starting leaking reinspection required | 9/28/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Perform annual test within 30 days | 9/28/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | Yes | No | Test overspeed valve om or before 6/1/23 | 4/5/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 4/6/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 4/6/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 4/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair emergency phone in car | 4/5/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 12/15/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Yes | No | Cleaning of pit not done--failed | 1/9/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service service testing and document on log in machine room | 7/30/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Door restricted not working |