Inspection
Inspection Details
Equipment ID
10701
10701
Inspection Date
2/7/2019
2/7/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
10
10
Governor Rope Pull
180/560
180/560
Door Closing Force
25
25
External ID
dd9fa83c-c972-4d06-819a-6f1c686a0baa
dd9fa83c-c972-4d06-819a-6f1c686a0baa
Location
Parkview Elderly Apts
4451 FOREST PARK AVE, SAINT LOUIS, MO
4451 FOREST PARK AVE, SAINT LOUIS, MO
Owner
The Habitat Company
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
Billing
Attn: The Habitat Company
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (E) - Machines | (E)1 | No | Yes | Repair or replace machine drive sheave. | 3/2/2019 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)6 | Yes | Yes | Replace governor and perform remainder of full load test. | 3/2/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean elevator pit. | 7/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Written maintenance control program shall be kept on site for each elevator. | 6/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be kept dry, clean & free of equipment or material not relating to the operation of the elevator | 3/26/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A MCP shall be provided for each unit & kept on site | 3/26/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit has trash and debris in it. Clean elevator pit | 3/27/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Elevator machine room has 2 inoperative light fixtures. Repair lighting | 3/27/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/22/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Category 5 full load testing shall be completed. | 5/27/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Elevator cab must have a permanent slip resistance floor installed. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room door shall be self-closing and self-locking | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency power must be tested annually. |