Inspection
Inspection Details
Equipment ID
23903
23903
Inspection Date
2/19/2019
2/19/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
0c1ab1b8-0d47-48ee-8e3b-05ef3630db5a
0c1ab1b8-0d47-48ee-8e3b-05ef3630db5a
Location
Fairfield Inn/ Residence
11920 WESTLINE INDUSTRIAL DR, SAINT LOUIS, MO
11920 WESTLINE INDUSTRIAL DR, SAINT LOUIS, MO
Owner
Midas Hospitality Group
1804 BORMAN CIRCLE DR, SAINT LOUIS, MO 63146-4161
1804 BORMAN CIRCLE DR, SAINT LOUIS, MO 63146-4161
Billing
Attn: Midas Hospitality Group
1804 BORMAN CIRCLE DR STE 100, SAINT LOUIS, MO 63146-4141
1804 BORMAN CIRCLE DR STE 100, SAINT LOUIS, MO 63146-4141
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall work. | 2/19/2019 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | Remove Water from pit | 11/1/2019 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Need maintenance control program on site posted on controller on or by next test | 12/21/2020 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Need testing procedures in the MCP on or before 1/1/22 | 12/20/2021 | ||
A17.1-2016 : Elevators | 5.6 - Governor-rope tension devices | 8.11.2.1.5(g) | Replace rusting conduit to Governor tail sheave switch 620.21 | 1/3/2023 | ||
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.2.1.5(a) | Channel pit floor to sump pump to drain standing water. 2.2.2.3 | 1/3/2023 | ||
A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(f) | Repair machine space lighting top of hoistway 2.7.6.3.2(c) | 1/3/2023 | ||
A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.6.3.2 (Re-Inspection) | x | Hoisting belts have rouge all over need to be replaced | 10/19/2023 | |
A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.19.3 | x | Replace rusting pipe to govenor weight tail switch | 10/19/2023 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | x | Replace rusting piping to governor weight tasil switch has not been corrected | 11/3/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | x | Reinspection for rusted piping for tail shiv in pit, not corrected. Will have until Jan 15, 2024 to complete | 1/15/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | x | Repair switch push buttons in phase 2 fire service panel in car |