Inspection
Inspection Details
Equipment ID
13372
13372
Inspection Date
12/18/2018
12/18/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Joseph Ammons
Joseph Ammons
Relief Valve Pressure
0
0
Slide
Governor Rope Pull
Door Closing Force
0
0
External ID
59064f03-0f9c-4a48-be9d-0f30b45d0893
59064f03-0f9c-4a48-be9d-0f30b45d0893
Location
State Capitol Building
201 E CAPITOL AVE, JEFFERSON CITY, MO
201 E CAPITOL AVE, JEFFERSON CITY, MO
Owner
State of MO- Capitol Bldg
301 W HIGH ST RM 590, JEFFERSON CITY, MO 65101-1517
301 W HIGH ST RM 590, JEFFERSON CITY, MO 65101-1517
Billing
Attn: OA-FMDC
PO BOX 809, JEFFERSON CITY, MO 65102-0809
PO BOX 809, JEFFERSON CITY, MO 65102-0809
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate on wall above lift. | 9/20/2025 | ||
| ASME A18.1-2005 : Lifts & Chairlifts | 2.1 - Runways | 2.1.1.2 | Space between upper landing door and platform exceeds 3". | 9/20/2025 | ||
| ASME A18.1-2005 : Lifts & Chairlifts | 2.1 - Runways | 2.1.1.3 | Space between lower landing door and platform exceeds 3/4". | 9/20/2025 | ||
| ASME A18.1-2005 : Lifts & Chairlifts | 2.11 - Emergency Signals | 2.11.1 | x | Emergency alarm not working. | 12/20/2023 | |
| ASME A18.1-2005 : Lifts & Chairlifts | 2.1 - Runways | 2.1.1.3 | Remove door handle from the inside lower landing door, potential pinch point exists. | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | Post operating certificate on wall above unit when received. | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | Space between upper landing door and platform exceeds 3" | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | Space between lower landing door and platform exceeds 3/4". | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | Emergency alarm not working. | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | Remove door handle from the inside of the lower landing door, pinch point exists. | 9/20/2025 | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | x | Space between upper landing door and platform exceeds 3". | 9/20/2025 | |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | x | Space between lower landing door and platform exceeds 3/4". | 8/19/2025 | |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 | x | Remove door handle from inside of the lower landing door. A pinch point exsists. | 8/19/2025 | |
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | x | Space between upper landing door and platform exceeds 3" | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | x | Space between lower landing door and platform exceeds 3/4" | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | x | Emergency alarm not working. | ||
| Missouri Minimum : Platform Lifts | (U) - Existing Vertical and Inclined Platform Lifts | (U)1 (Re-Inspect) | x | Remove door handle from inside lower landing door, pinch point exists. |