Inspection
Inspection Details
Equipment ID
18267
18267
Inspection Date
1/29/2019
1/29/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
956bdaee-2c6d-4f02-87de-30d16ab771f9
956bdaee-2c6d-4f02-87de-30d16ab771f9
Location
City Museum
701 N 15TH ST, SAINT LOUIS, MO
701 N 15TH ST, SAINT LOUIS, MO
Owner
City Museum
701 N 15TH ST, SAINT LOUIS, MO 63103-1931
701 N 15TH ST, SAINT LOUIS, MO 63103-1931
Billing
Attn: City Museum
701 N 15TH ST STE 29, SAINT LOUIS, MO 63103-1925
701 N 15TH ST STE 29, SAINT LOUIS, MO 63103-1925
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (A) - Hoistways | (A)4 | Where freight elevator hoistway doors or gates are of open or lattice construction, said gate shall be constructed as to reject a ball two inches in diameter. The holes in the car gate shall be repaired. | 12/7/2020 | ||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | Each freight car enclosure shall have a "No Passengers" sign conspicuously posted. | 12/7/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | The mainline disconnect duct shall have a cover. | 12/7/2020 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Hoistway access means shall be provided at the top and bottom floor. | 12/7/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The radiator in the machine room shall be properly fastened or removed. | 12/7/2020 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | All hoistway doors shall have pull straps. | 12/7/2020 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | A category 5 full load test shall be witnessed in 2020. | 9/28/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/23/2022 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 6/23/2022 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | Pull straps shall be installed on all hoistway doors. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)6 | Machines, motors, and disconnects shall be conspicuously marked. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | The water on the machine room floor shall be removed, and the leak repaired. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Access to the machine room shall be safe. The brickwork above the machine room door and on the stairway landing is falling down, and shall be repaired. | 6/23/2022 | ||
| MO Minimum : Elevators | (I) - Pits | (I)8 | The drain hole in the pit floor shall be covered flush with the floor. | 6/23/2022 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | The exposed wiring behind the pit ladder shall be enclosed. (This is a hazard when accessing the pit and using the ladder because it cannot be seen from the hallway.) | 6/23/2022 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | The movement of the safety drum rope, starting from a fully retracted position, must not exceed 36". (It pulled out 47") | 3/1/2022 | |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | Replace missing top canopy panels. Each freight elevator car enclosure shall be provided with a top. The top may be solid or open-work construction and shall be of metal. The open work shall reject a ball two inches (2") in diameter. Car tops shall be constructed to sustain a load of two hun- dred (200) pounds applied at any point on the car top. The top shall not have hinged or folding panels other than the emergency exit cover. | 12/8/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Access means shall be provided at one (1) upper landing to permit access to the top of the car, and at the lowest landing if this landing is the normal point of access to the pit. | 12/8/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Access means shall be provided at one (1) upper landing to permit access to the top of the car, and at the lowest landing if this landing is the normal point of access to the pit. | 12/8/2025 | ||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Bulbs or tubes in the cab enclosure shall be guarded to prevent breakage | 12/8/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace covers on exposed wiring on the car top and SOS switch. | 12/8/2025 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean Pit |