Inspection
Inspection Details
Equipment ID
26824
26824
Inspection Date
8/14/2026
8/14/2026
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Scott Bishop
Scott Bishop
Relief Valve Pressure
NA
NA
Slide
Softset
Softset
Governor Rope Pull
Softset
Softset
Door Closing Force
18
18
External ID
df26ced0-fa47-484a-ad3c-658ec9318925
df26ced0-fa47-484a-ad3c-658ec9318925
Location
Vande East Apartments
3835 Foundry Way, St Louis, MO
Phone: (314) 471-0070
Email: Todd.Rogan@newandfound.com
3835 Foundry Way, St Louis, MO
Phone: (314) 471-0070
Email: Todd.Rogan@newandfound.com
Owner
Attn: Director of Property Management
Vande East Partners, LLC
319 N 4th St. Suite 1000, St. Louis, MO 63102
Phone: (314) 231-5700
Vande East Partners, LLC
319 N 4th St. Suite 1000, St. Louis, MO 63102
Phone: (314) 231-5700
Billing
Attn: Manager
2B Residential
3835 Foundry Way, St. Louis, MO 63110
Phone: (833) 739-0768
Email: onefoundry@2Bresidential.com
2B Residential
3835 Foundry Way, St. Louis, MO 63110
Phone: (833) 739-0768
Email: onefoundry@2Bresidential.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | A record of firefighters service operation, tested mothly as required by 8.6.11.1, with identification of the person(s) that perfomed the operation and the date shall be avaliable on site. | 8/14/2026 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | No | No | Feeder location for the main and lighting branch circuits shall be marked on the disconnects. | 8/14/2026 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | No | No | An electrical box cover is missing in the overhead and shall be replaced. | 8/14/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 2-WAY COMMUNICATION DEVICE SHALL WORK.Voice works, Camera works, text does not | |
| A17.1-2016 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 2.4.2 | Yes | No | Counterweight runby(5") is less than required minimum of 6" | |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | No | No | Feeder locations for the main and lighting branch circuits shall be marked on the disconnects. | |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | A code compliant MCP and related on-site documentation shall be provided in the machine room | |
| A17.1-2016 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | No | No | Car top work light does not work. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | A data plate, permanently and securely attached, shall be provided in the pit, in the vicinity of the Counterweight buffer indicating Maximum designed counterweight runby | |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | No | No | Control Space(6th Floor Lobby) shall have at least one(1) GFCI outlet. Currently no outlet. | |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | No | No | An electrical box cover is missing in the overhead and shall be replaced. | |
| A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13 | No | No | Adjust outer upthrust roller bearings for proper clearance to door hanger track.(Floors: 2 & 4) | |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit shall be kept clean. Remove excess debris. |