Inspection
Inspection Details
Equipment ID
14877
14877
Inspection Date
6/8/2017
6/8/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
Location
Independence Tower Apartments
728 N Jennings Rd, Independence, MO
Phone: (816) 257-1400
728 N Jennings Rd, Independence, MO
Phone: (816) 257-1400
Owner
Independence Tower Apartments
728 Jennings Rd, Independence, MO 64056
728 Jennings Rd, Independence, MO 64056
Billing
Attn: Independence Tower Apartments
728 Jennings Rd, , MO 64056
728 Jennings Rd, , MO 64056
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | No rope data tags | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | Car door restrictor not working | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | NoGov. rope data tags | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | Emg. phone not working | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | Car top dirty an oily shall not be usd for storage | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | No antirotation device on car or counterweight shackles | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | Water an oil an debris on pit floor | 8/20/2019 | |
conversion | conversion | conversion - reinspect | x | Missing fire hat cover in car | 8/20/2019 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.11.2.1.1(o) | missing fire hat jewell in car an hall | 11/18/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | emg lt an bell not working | 9/7/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | no anti spin cable 2.20.9.8 or8.6.3.3.1 | 11/18/2024 | ||
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | lt an bell not working | 9/7/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | x | Provide working phone and emergency lights and bell | 9/7/2022 |
MO Minimum : Elevators | (I) - Pits | (I)1 | Remove standing water and debris from pit | 9/7/2022 | ||
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Provide rope data tags for car and governor | 9/7/2022 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | Supply capacity plate for car | 9/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | x | Provide work door restrictor on unit | 9/7/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | Provide anti spin cables for car and counterweight | 9/7/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Provide rope data tags. | 11/1/2024 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Car door restrictor cam worn, not holding completely. | 11/1/2024 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | REMOVE TRASH AND DEBRIS FROM PIT | 11/1/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | PROVIDE WORKING PHONE | 11/1/2024 |