Inspection
Inspection Details
Equipment ID
18285
18285
Inspection Date
2/27/2019
2/27/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
1f6fc52e-aa08-49c4-ae24-8c6e8831e346
1f6fc52e-aa08-49c4-ae24-8c6e8831e346
Location
Dicks Sporting Goods
200 W COUNTY CTR, DES PERES, MO
200 W COUNTY CTR, DES PERES, MO
Owner
Westfield- Dicks
44 W COUNTY CTR, DES PERES, MO 63131-3724
44 W COUNTY CTR, DES PERES, MO 63131-3724
Billing
Attn: Westfield- Dicks
80 W COUNTY CTR, DES PERES, MO 63131-3701
80 W COUNTY CTR, DES PERES, MO 63131-3701
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Escalators | 8.13 - Handrail systems and safety devices | 802.4 | No | No | Replace left side up handrail inlet switch. Switch is broken. Reinspection Required. | 11/5/2020 |
| A17.1-1996 : Escalators | 7.9 - Steps and upthrust device | 802.5 | No | No | Replace broken step thread. | 11/5/2020 |
| A17.1-1996 : Escalators | 7.9 - Steps and upthrust device | 802.5 | No | No | Replace broken step tread. | 11/5/2020 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 1008.2l | Yes | Yes | Step chains are severely worn. Steps and risers do not mesh. Red tagged out of service. Repair and reinspect. | 7/21/2020 |
| A17.1-1996 : Escalators | 7.9 - Steps and upthrust device | 802.5 | No | No | Replace broken step thread. | 11/5/2020 |
| A17.1-1996 : Escalators | 7.9 - Steps and upthrust device | 802.5 | No | No | Broken step tread | 8/31/2022 |
| A17.1-1996 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 1206.6a | No | No | Clean pits/ drip pans. | 8/31/2022 |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.15.19 | No | No | Failed index test. | 8/31/2022 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 1008.2l | Yes | No | Lower end “crab track” excessively noisy. | 8/31/2022 |
| A17.1-1996 : Escalators | 8.4 - Drive machine and brake | 804 | Yes | Yes | Brake torque testing has failed. Repair or replacement of the brake assembly is required. Reinspection is required before the unit can be returned to service. | 12/10/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Escalator inspection is not completed. only the bottom machine space and the truss area has been completed. Reinspection is required. | 12/10/2024 |
| A17.1-1996 : Escalators | 8.4 - Drive machine and brake | 804 | Yes | Yes | Brake test failed, unit removed from service. | 12/13/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide index testing, record results. | 12/13/2024 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide index testing, record results. | 3/5/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Provide unit clean down. | 12/2/2025 |