Inspection
Inspection Details
Equipment ID
16815
16815
Inspection Date
12/28/2017
12/28/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
320
320
Slide
Governor Rope Pull
Door Closing Force
19
19
External ID
Location
Data Max Office Systems
6717 Waldemar, St. Louis, MO
Phone: (314) 633-1400
6717 Waldemar, St. Louis, MO
Phone: (314) 633-1400
Owner
Sumner Group Inc
2121 Hampton Ave, St. Louis, MO 63139
2121 Hampton Ave, St. Louis, MO 63139
Billing
Attn: Sumner Group Inc dba Datamax St. Louis
6717 Waldemar, , MO 63139
6717 Waldemar, , MO 63139
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emergency phone not working | 1/9/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | No | No | Lower door reopening device shall work. | 1/29/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | The use of oil recovery system by automatic means prevents proper monitoring of gland packing and seals. | 12/1/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove scavenger unit from pit. | 12/1/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Provide code complaint means to collect oil in pit. | 12/1/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Car phone goes to 911. Reprogram to proper provider. | 7/12/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide MCP. | 12/1/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Observed fluid coming from jack head in pit. Determine cause, repair as needed. | 12/1/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 12/1/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator ADA telephone inside the elevator is not working properly. Check and repair the phone line of this phone for proper operation and passenger safety. Reinspection required. | 4/29/2024 |