Inspection
Inspection Details
Equipment ID
22183
22183
Inspection Date
12/22/2017
12/22/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Raymond Stidham
Raymond Stidham
Mechanic Name
Relief Valve Pressure
n/a
n/a
Slide
instantanious
instantanious
Governor Rope Pull
n/a
n/a
Door Closing Force
n/a
n/a
External ID
Location
Buick Mine/ Mill
270 Forest Rd 2231, Boss, MO
Phone: (573) 626-4855
270 Forest Rd 2231, Boss, MO
Phone: (573) 626-4855
Owner
The Doe Run Co
P.O Box 500, Viburum, MO 65566
P.O Box 500, Viburum, MO 65566
Billing
Attn: The Doe Run Co
P.O Box 500, , MO 65566
P.O Box 500, , MO 65566
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Pit must be enclosed with solid material. | 4/30/2020 | ||
conversion | conversion | n/a | Must enclose intire hoistway. | 4/30/2020 | ||
conversion | conversion | n/a | All landings must be enclosed with solid material to a height of 8'. | 4/30/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | The emergency light and alarm shall be operational and shall be equipped with a 4 hour battery back-up. | 7/11/2022 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | Brake coil shall not be fed off hoist motor circuit. It shall have it's own circuit with two contacts. | 1/5/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | x | Rope tags and code data tag required. | 1/5/2024 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | Unit left out of service. Floor stops need to be adjusted. | 1/5/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No MCP provided due to no maintenance contract. | |||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | x | Unit failed 125% test. Red-tag issued. | 3/7/2025 |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | There is no MCP due to no maintenance contract. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in-car alarm does not work. | 3/7/2025 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The remainder of the annual and category 5 test shall be completed. Inspection stopped due to red tag. | 3/7/2025 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in-car alarm does not work. Take corrective action and re-test. |