Inspection
Inspection Details
Equipment ID
11093
11093
Inspection Date
3/29/2019
3/29/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michial Linenfelser
Michial Linenfelser
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
23
23
External ID
c2a6115e-702b-4426-b6cd-ae036b65cc03
c2a6115e-702b-4426-b6cd-ae036b65cc03
Location
Grandview Tower
300 S GRAND BLVD, SAINT LOUIS, MO
300 S GRAND BLVD, SAINT LOUIS, MO
Owner
Grandview Apartment Homes LLC
300 S GRAND BLVD, SAINT LOUIS, MO 63103-2448
300 S GRAND BLVD, SAINT LOUIS, MO 63103-2448
Billing
Attn: Grandview Apartment Homes LLC % The Wellington Group
1715 DEER TRACKS TRL STE 220, SAINT LOUIS, MO 63131-1855
1715 DEER TRACKS TRL STE 220, SAINT LOUIS, MO 63131-1855
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 3.23 - Suspension rope | 1001.2(c)(29) | x | The counterweight is within 1 inch of touching the oil buffer when the elevator travels to the top floor. The counterweight buffer has a buffer switch that will activate when the oil buffer is compressed thereby resulting in a elevator shut down. The hoist ropes shall be shortened to provide a minimum runby of 6 inches. | 5/14/2020 | |
A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Provide annual testing of elevator recall and power selector switch on standby power operation. | 2/17/2021 | |
A17.1-1996 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 1001.2(e)(2) | x | Provide current code compliant runby | 9/14/2022 | |
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | Clean pit | |||
A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | x | Provide cat 5 generator test | 9/14/2022 | |
A17.1-1996 : Elevators | 4.12 - Standby power selection switch | 1001.2(d)(12) | Provide testing of generator selector switch | |||
A17.1-1996 : Elevators | 3.17 - Door and gate equipment | 1001.2(c)(23) | Hoistway door missing bottom door guide, 10th floor left door | |||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Clean car top | |||
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | x | Provide phase 1 and 2 testing | 9/14/2022 | |
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | Door restrictor inoperable. Re-inspection required | 3/8/2023 | |
A17.1-2016 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.6.4.11 Runby (Re-Inspect) | x | Runby shall be adjusted to maintain at least 6" of runby. Re-inspection required | 3/8/2023 | |
MO Minimum : Elevators | (A) - Hoistways | (A)3 | Fire tabs shall be installed on 1st floor doors | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be cleaned, including hoistway & cartop | |||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be on display in the machine room | |||
A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Provide annual testing of elevator recall & power selector switch on standby power operation. Reschedule for emergency power test. Re-inspection required | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display updated Missouri Operating Certificate in machine room |