Inspection
Inspection Details
Equipment ID
977
977
Inspection Date
4/10/2019
4/10/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
David Scott
David Scott
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
28/26
28/26
External ID
e9a739be-1e74-4da5-9801-bd4ac1c0a5c6
e9a739be-1e74-4da5-9801-bd4ac1c0a5c6
Location
Bank of America Concord Plaza
5353 S LINDBERGH BLVD, SAINT LOUIS, MO
5353 S LINDBERGH BLVD, SAINT LOUIS, MO
Owner
Ariel investment LLC
717 THE HAMPTONS LN, TOWN AND COUNTRY, MO 63017-5901
717 THE HAMPTONS LN, TOWN AND COUNTRY, MO 63017-5901
Billing
Attn: Ariel investment LLC
8825 PAGE AVE, SAINT LOUIS, MO 63114-6105
8825 PAGE AVE, SAINT LOUIS, MO 63114-6105
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Post current State certificate in machine room | 4/18/2019 |
| conversion | conversion | n/a | No | No | Repair electric eye on front car door | 4/18/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 4/18/2019 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | No | No | Photo eye on the car door is functional during fire service recall. Photo eye must be overridden during fire service Phase 1 and 2. | 3/19/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/7/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. The pit needs to be cleaned. | 7/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Cylinder packing is worn and leaking, repair/ replace as needed. | 4/20/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Observed standing water in the pit, confirm sump pump is working, if not-replace. | 4/20/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/20/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water shall not be allowed to accumulate in the pit. This is a multi-year violation. If not corrected by next annual inspection a re-inspection will be required. | 4/20/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Sump pump and cover has been removed and shall be replaced. | 4/20/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No MO State operating certificate in the machine room. |