Inspection
Inspection Details
Equipment ID
12769
12769
Inspection Date
1/26/2018
1/26/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
Location
McCormack House
4575 Cadet Ave, St. Louis, MO
Phone: (314) 371-2525
4575 Cadet Ave, St. Louis, MO
Phone: (314) 371-2525
Owner
McCormack House
4575 Cadet Ave, St. Louis, MO 63110
4575 Cadet Ave, St. Louis, MO 63110
Billing
Attn: McCormack House
4575 Cadet Ave, , MO 63110
4575 Cadet Ave, , MO 63110
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Electric eyes are not working. | 9/19/2019 | ||
A17.1-1996 : Elevators | 1.1 - Door Re-opening device | 1001.2(a)(1) | Door re-opening device shall work. | 9/19/2019 | ||
A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | Remove non-electrical material from machine space. | 9/19/2019 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | Emergency light shall work. | 12/10/2019 | |
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency alarm bell shall work. | 12/10/2019 | |
A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | x | OSV is not sealed or tagged, notified on last visit, must be sealed & tagged within 90 days. | 5/27/2022 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Remove debris in pit | 5/27/2022 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit lighting in-operable | 5/27/2022 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency communication inoperable. Re-inspection required | 6/14/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Debris in pit | 8/4/2023 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit lighting inoperable. | 8/4/2023 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | reinspection of elelvator phone. Still nto working. Repair phone. Reinspect by 7/14/23 (30 days) | 7/13/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Reinspection of debris in elelvator pit. Still dirty. Clean elevator pit. | 8/15/2023 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Reinspection fo elelvator pit lights. Still not working. Repair lights. | 8/15/2023 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Re-inspection of elevator pit lights, still not working. Need to repair pit lights | 7/13/2023 |