Inspection
Inspection Details
Equipment ID
1870
1870
Inspection Date
4/8/2019
4/8/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
19
19
External ID
4ca275d6-5d75-4ce2-bf5e-edf8d7df1e62
4ca275d6-5d75-4ce2-bf5e-edf8d7df1e62
Location
Gibson Elementary School
9926 FONDA DR, SAINT LOUIS, MO
9926 FONDA DR, SAINT LOUIS, MO
Owner
Riverview Gardens School District
1370 NORTHUMBERLAND DR, SAINT LOUIS, MO 63137-1413
1370 NORTHUMBERLAND DR, SAINT LOUIS, MO 63137-1413
Billing
Attn: Riverview Gardens School District
1370 NORTHUMBERLAND DR, SAINT LOUIS, MO 63137-1413
1370 NORTHUMBERLAND DR, SAINT LOUIS, MO 63137-1413
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | Perform OSV test on or before next annual inspection. | 7/30/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean debris out of pit | 5/31/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired, have serviced or replaced | 5/15/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 5/15/2026 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | Stop switch shall be repaired in the car operator panel. Re-inspection required | 4/10/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate shall be displayed in elevator machine room. | 5/15/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit conditions shall be clean, dry, and clear of all debris. | 5/15/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm inoperable, repair or replace as needed. | 5/21/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Emergency lighting inoperable, repair or replace as needed. | 5/15/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. At least 3" of water is in pit. Sump pump should be inspected and repaired or replaced | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | The elevator machine rom cannot be used for storage. Remove the itelms being stored in the machine room to provide room for maintenance to be performed | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test is incomplete, relief test must be performed and door pressure measured. Re-inspection required |