Inspection
Inspection Details
Equipment ID
13604
13604
Inspection Date
4/22/2019
4/22/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michial Linenfelser
Michial Linenfelser
Mechanic Name
Robert Kehm
Robert Kehm
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
24
24
External ID
26808881-eb98-4d85-b3c7-d3cd99b070b5
26808881-eb98-4d85-b3c7-d3cd99b070b5
Location
Branscome Apartments
5370 PERSHING AVE, SAINT LOUIS, MO
5370 PERSHING AVE, SAINT LOUIS, MO
Owner
Branscome Apartments
5370 PERSHING AVE, SAINT LOUIS, MO 63112-1750
5370 PERSHING AVE, SAINT LOUIS, MO 63112-1750
Billing
Attn: Phillip H Barron Realty
1423 S BIG BEND BLVD STE 200, RICHMOND HEIGHTS, MO 63117-2264
1423 S BIG BEND BLVD STE 200, RICHMOND HEIGHTS, MO 63117-2264
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | There is no fire extinguisher in the machine room, as required. Provide an ABC type extinguisher of proper size for the room. | 4/20/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine room is expired. Replace or have serviced | 7/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone in car is not answered. Repair same | 7/13/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate needs to be displayed in machine room | 7/27/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Unit failed to operate during testing. Perform the following tests to complete inspection: full load full speed safeties, unintended motion up direction, full load unintended motion down direction, governor trip speed, governor switch trip speed, governor rope pull out, governor rope pull thru | 7/13/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency two way communication device is inoperable. Repair or replace | 4/29/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine room has a leaking pipe causing water to leak on floor. Repair leak to maintain a clean machine floor | 5/2/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Take corrective action and re-test. | 5/12/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | 5/20/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Water shall not be allowed to accumulate on pit floors. | 5/20/2025 |