Inspection
Inspection Details
Equipment ID
15761
15761
Inspection Date
4/2/2019
4/2/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Thomas Jimas
Thomas Jimas
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
f402ae21-bd89-4ba9-9e53-44eff4182874
f402ae21-bd89-4ba9-9e53-44eff4182874
Location
Lambert St. Louis Int'l Airport
LAMBERT FIELD, ST. LOUIS, MO
LAMBERT FIELD, ST. LOUIS, MO
Owner
St. Louis Airport Authority
PO BOX 10036, SAINT LOUIS, MO 63145-0036
PO BOX 10036, SAINT LOUIS, MO 63145-0036
Billing
Attn: St. Louis Airport Authority
10701 LAMBERT INTERNATIONAL BLVD, SAINT LOUIS, MO 63145-1000
10701 LAMBERT INTERNATIONAL BLVD, SAINT LOUIS, MO 63145-1000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Left-hand side handrail is cracked. | 4/2/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(H) | No | No | The demarcation lights shall be operational. | 7/26/2019 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Display a current MO State operating certificate. | 4/12/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 4/12/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | The left side handrail shall not have cracks. | 3/10/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.2 Escalator Step-to-Skirt Clearance | Yes | No | Unit failed skirt/performance index test. Make necessary corrections and re-test. | 4/18/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Replace the broken comb segments at the bottom of the unit. | 3/10/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Correct the source of the leaks at the drive machine gear box. | 3/10/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | Yes | No | Right handrail is cracked and showing extreme wear. The handrail shall be replaced. | 7/25/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.8 Escalator Signs | No | No | Broken sign illistrating to hold onto the handrail shall be replaced. |