Inspection
Inspection Details
Equipment ID
12877
12877
Inspection Date
6/6/2018
6/6/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Relief Valve Pressure
Slide
4"
4"
Governor Rope Pull
150 / 700
150 / 700
Door Closing Force
F 18 R 16
F 18 R 16
External ID
Location
City Place 1
1 City Place Drive, Creve Coeur, MO
Phone: (314) 787-1976
1 City Place Drive, Creve Coeur, MO
Phone: (314) 787-1976
Owner
City Place Owner LLC
2 City Place Ste 460, St Louis, MO 63102
2 City Place Ste 460, St Louis, MO 63102
Billing
Attn: CBRE
# 6 City Place, , MO 63141
# 6 City Place, , MO 63141
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | Phone is cab does not work | 5/22/2019 | |
| conversion | conversion | conversion - reinspect | x | Cab Emergency lights do not work | 5/22/2019 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | Unable to test the emergency car lighting and signaling devices. The 110V disconnect for those systems could not be located. Locate and label the disconnect so the emergency systems can be tested properly. | 6/23/2020 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be on display in the machine room | |||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work, needs repair or replaced. Re-inspection required | 6/8/2023 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The following tests still need to be performed to complete the cat 5 inspection: full load, full speed safeties and 125% brake | 6/7/2023 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display updated Missouri Operating Certificate in machine room | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Place current state operating certificate in elevator machine room | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Elevator pit light does not work, new light bulb did not rectify problem. Problem may be in pit light wiring or light fixture. | |||
| MO Minimum : Elevators | (I) - Pits | (I)7 | Elevator pit stop switch is loose and needs to be secured to wall in pit. | |||
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | Rear elevator car door re-opening device does not work. Electric eye repair door re-opening device |