Inspection
Inspection Details
Equipment ID
3393
3393
Inspection Date
6/7/2017
6/7/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Harris
David Harris
Mechanic Name
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Benton Square
6th & Walnut, Rolla, MO
Phone: (573) 468-3141
6th & Walnut, Rolla, MO
Phone: (573) 468-3141
Owner
FCNB Property Management LLC
P.O. Box 2109, Rolla, MO 65402
P.O. Box 2109, Rolla, MO 65402
Billing
Attn: FCNB Property Management LLC
P.O. Box 2109, , MO 65402
P.O. Box 2109, , MO 65402
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | oil/water in pit | 7/8/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | water/oil in pit | 7/8/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | oil in pit--elevator needs to have new packings install | 7/8/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | oil in pit--clean--repack | 7/28/2021 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Oil in pit- clean | 12/13/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Fire extinguisher in machine room is out of date | 2/14/2025 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.35 - Supply Line and Shutoff Valve | 3.19 | Overspeed valve has seal but not dated. Needs to be tested unless a proper date can be confirmed | 2/14/2025 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine door does self close but can be left in unlocked position. Needs to only able to open from outside by a key | 2/14/2025 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working | 2/14/2025 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Sump pump piping runs directly over elevator machine & controller piping is not guarded or guttered. | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone failed to operate appears phone line has been removed. | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Light does not give off enough illumination to provide the required lighting at floor lever in front of controller. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Lighting in machine room is hanging from the ceiling, secured only by wire nuts. |