Inspection
Inspection Details
Equipment ID
19741
19741
Inspection Date
4/4/2019
4/4/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
f64f92c2-1289-4a0f-a48a-6f6dcc52c304
f64f92c2-1289-4a0f-a48a-6f6dcc52c304
Location
Bommarito Business Center
320 BROOKES DR, HAZELWOOD, MO
320 BROOKES DR, HAZELWOOD, MO
Owner
BB Realty North LLC
320 BROOKES DR, HAZELWOOD, MO 63042-2736
320 BROOKES DR, HAZELWOOD, MO 63042-2736
Billing
Attn: BB Realty North LLC
320 BROOKES DR, HAZELWOOD, MO 63042-2736
320 BROOKES DR, HAZELWOOD, MO 63042-2736
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Possible single bottom jack. | 1/5/2018 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | The in car emergency stop switch (toggle) is broken and shall be replaced or repaired. | 4/4/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | 8.6.5.8 - Possible single bottom jack. Based off of serial number unit is likely a double bottom type. Submit documentation to the state and leave documentation on site that confirms jack type. | 1/15/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be guarded to prevent breakage or accidental contact. | 1/15/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display a copy of the current state operating certificate. | 1/15/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Possible single bottom jack. Provide documentation that hydraulic jack is of double bottom type or perform necessary correction. | 11/17/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be obtained and displayed in the elevator machine room. | 11/17/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 11/17/2025 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.14.2 Hydraulic Cylinders and Pressure Piping | Yes | Yes | Excessive oil leaking from the jack. Jack is blown. Elevator Red Tagged. | 9/2/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. | 7/11/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/1/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be obtained and displayed in the elevator equipment room in a non-combustible frame. | 2/6/2026 |