Inspection
Inspection Details
Equipment ID
2447
2447
Inspection Date
5/6/2019
5/6/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Terhune
Michael Terhune
Mechanic Name
Donald Mueller
Donald Mueller
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
886f714d-458a-408f-9601-a26855402bc0
886f714d-458a-408f-9601-a26855402bc0
Location
Memorial Union
HITT ST AT UNIVERSITY AVE, COLUMBIA, MO
HITT ST AT UNIVERSITY AVE, COLUMBIA, MO
Owner
Attn: Jennifer Smith - Facility Operations
UMC-General Services
180 General Services Bldg, COLUMBIA, MO 65201
Phone: (573) 884-5300
Email: smithjenni@missouri.edu
UMC-General Services
180 General Services Bldg, COLUMBIA, MO 65201
Phone: (573) 884-5300
Email: smithjenni@missouri.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 10/13/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Provide sump hole cover | 10/13/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide a proper code data plate for mod | 12/14/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide lighting of the 19fc at floor in all machine room areas | 12/14/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.1 Making Safety Devices Inoperative or Ineffective (Re-Inspection) | No | No | Provide sump hole cover | 8/4/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 8/4/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Auxiliary power lowering is not working. Re-inspection required | 7/10/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The lighting in the elevator machine room is not sufficient, the lighting shall not be less than 10 foot candles at the floor level | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 3.26.10 | Yes | No | Battery lowering device is not working, needs repaired. Re-inspection required | 8/7/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Yes | No | Battery lowering device is not working. Re-inspection required |