Inspection
Inspection Details
Equipment ID
16422
16422
Inspection Date
5/3/2019
5/3/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Matthew Martin
Matthew Martin
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
16
16
External ID
82364e09-f170-4fb2-b368-0f1592c7847b
82364e09-f170-4fb2-b368-0f1592c7847b
Location
Grand Building
520 N GRAND BLVD, SAINT LOUIS, MO
520 N GRAND BLVD, SAINT LOUIS, MO
Owner
K.P.K. Associates
516 GRAND, ST. LOUIS, MO 63103
516 GRAND, ST. LOUIS, MO 63103
Billing
Attn: K.P.K. Associates
516 N GRAND BLVD, SAINT LOUIS, MO 63103-1007
516 N GRAND BLVD, SAINT LOUIS, MO 63103-1007
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV installed and not sealed or tagged. Perform OSV test on or before next annual inspection. | 6/16/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 6/16/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | Provide current year tested fire extinguisher in the elevator machine room. | 6/16/2025 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | Yes | No | Cylinder packing (R) is worn and leaking. | 3/21/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 6/16/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | Yes | No | Provide current year tested fire extinguisher in the elevator machine room. | 10/15/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Clean the pit (oil). | 6/16/2025 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | Yes | No | Cylinder packing(r) is worn and leaking, repair as needed. | 10/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean the car top. | 6/16/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide machine room door to be self closing and locking. (Currently pull and it is open) | 6/16/2025 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | Yes | No | Cylinder packing is worn and leaking, repair as needed. | 1/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Cylinder packing is beginning to leak and shall be replaced | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Means of two- way communication are inoperable and shall be repaired or replaced. |