Inspection
Inspection Details
Equipment ID
18721
18721
Inspection Date
2/7/2018
2/7/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
R 23 R 21
R 23 R 21
External ID
Location
City Place 2
2 City Place Dr, Creve Coeur, MO
Phone: (314) 993-5800
2 City Place Dr, Creve Coeur, MO
Phone: (314) 993-5800
Owner
City Place Owner LLC
2 City Place Ste 460, St Louis, MO 63102
2 City Place Ste 460, St Louis, MO 63102
Billing
Attn: CBRE
# 6 City Place, , MO 63141
# 6 City Place, , MO 63141
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair Car emergency lights | 11/17/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | A drive belt on the car door operator motor is missing. Replace belts for a smooth operation of the car door. | 11/17/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The emergency car lighting is not operational. The fixture shall be repaired to operate. | 2/14/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light and alarm bell do not work. | 11/19/2020 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | Yes | Suspension ropes are undersized and have considerable rouge. Red tagged elevator. | 11/19/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | 5 year testing incomplete. Must complete all weight test to finish category 5 testing | 1/31/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state certificate shall be displayed in the machine room | 11/17/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell in elevator cab is not working on normal power, needs repaired. Re-inspection required | 11/13/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Front door restrictor does not work, needs repaired. Re-inspection required | 11/13/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm signal inoperable and shall be repaired, or replaced. | 11/17/2025 |