Inspection
Inspection Details
Equipment ID
15438
15438
Inspection Date
5/7/2019
5/7/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dennis Drinkard
Dennis Drinkard
Mechanic Name
Michael Bales
Michael Bales
Relief Valve Pressure
820
820
Slide
0
0
Governor Rope Pull
0
0
Door Closing Force
16
16
External ID
799fdf80-88a9-41fe-b0d3-6f8a38a33e22
799fdf80-88a9-41fe-b0d3-6f8a38a33e22
Location
Northeast Baptist Church
619 E LINCOLN ST, CLINTON, MO
619 E LINCOLN ST, CLINTON, MO
Owner
Northeast Baptist Church
619 E LINCOLN ST, CLINTON, MO 64735-1649
619 E LINCOLN ST, CLINTON, MO 64735-1649
Billing
Attn: Northeast Baptist Church
619 E LINCOLN ST, CLINTON, MO 64735-1649
619 E LINCOLN ST, CLINTON, MO 64735-1649
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 3.3 - Top-of-car operating device | 204.1g | No | No | Top of car inspections not working. Did test safeties. | 8/31/2020 |
| A17.1-1996 : Elevators | 3.3 - Top-of-car operating device | 210.1d | No | No | Top of Car Inspection Operation not working properly. Will not move past the next floor's door zone switch in either direction. | 8/31/2020 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Yes | No | Pit Light not working. | 11/24/2020 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.4.8 Machine Room and Machinery Space | No | No | the machinery space is not separated from the rest of the room, item were piled on and around the elevator equipment with no clear work space | 4/12/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.3.1.5(a) | No | No | the pit light was not working, the light bulb was burnt out | 4/12/2021 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4 Instructions for Locating Maintenance Records | No | No | need to start maintenance control program, there was no records on site | 4/12/2021 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.11.3.1.1(e) | No | No | replace burnt out cab ceiling light blub | 4/12/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.3.1.5(a) | No | No | pit light bulb is burnt out and needs to be replaced | 6/3/2021 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.11.2.1.2(gg) | Yes | Yes | the 5 year test was due in 2021, don't have record of it being done. slack rope type safeties. | |
| A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.11.3.1.3(r) | No | No | could not get the door on the 2nd landing to open automatically, had to push them open. door operator worked fine on the other landing on that side. could not find any obstructions preventing that door from opening. | 6/3/2021 |